INDUSTRIAL FAN

Industrial Exhaust Fan

Model: NE-EF Series

Airflow
4,600 – 55,000 m³/h
Blade size
350 – 1400 mm
Motor power
0.20 – 1.5 kW
Noise
≈ 65 dB

Sizes and quantities quoted to your site. Delivery across Bangladesh.

Need a heavy-duty industrial exhaust fan in Bangladesh? NextEdge BD supplies box-type exhaust fans with galvanized steel frames, automatic louver shutters and large balanced blades. They pull hot, humid and dusty air out of factories, workshops and warehouses quickly, at a low running cost.

  • 55,000m³/h max airflow
  • 16″–62″Frame size range
  • 0.20–1.5kW motor options
  • ≈65 dBRunning noise

What Is an Industrial Exhaust Fan?

An industrial exhaust fan is a large wall-mounted fan that removes stale air from a building. Mounted in a wall opening, it pulls hot air, moisture, smoke, dust and odours out of the room, while fresh air enters through doors, windows or cooling pads on the opposite wall. This steady air exchange keeps the workplace cooler and healthier, and it protects machines and stored goods from heat and damp. You can learn more about how this works in this guide to building ventilation.

Industrial exhaust fan features – galvanized frame, louver shutter and balanced blades

Key Features of Our Industrial Exhaust Fans

Very high airflow

Large blades move up to 55,000 m³/h, so one fan can ventilate a big floor area.

Galvanized steel frame

A rust-resistant box frame stands up to humid, dusty factory conditions.

Automatic louver shutter

The louvers open when the fan runs and close when it stops, keeping out rain, dust and birds.

Low power, long hours

Efficient 0.20–1.5 kW motors are built for 12 to 24 hours of daily running.

Balanced blades

Dynamically balanced blades run smoothly with low vibration and around 65 dB noise.

Easy wall installation

Fits straight into a wall opening or window frame, with a safety guard on the back.

Where Industrial Exhaust Fans Are Used

An industrial exhaust fan is the most common ventilation solution in Bangladesh factories:

  • Garment factoriesRemove heat from sewing, cutting and finishing floors.
  • Textile & dyeing millsClear steam, humidity and chemical smell.
  • Pharma & food plantsKeep production areas cool and control humidity.
  • Printing & packagingRemove ink fumes, glue smell and machine heat.
  • WarehousesStop heat and damp from damaging stored goods.
  • Workshops & foundriesPull out smoke, fumes and hot air from machines.
  • Plastic & rubber factoriesClear hot air and fumes from moulding machines.
  • Cooling pad systemsPair with evaporative pads for a cooler floor.
Industrial exhaust fan applications in garment factories, workshops and warehouses

How Many Industrial Exhaust Fans Do You Need?

The number of fans depends on the size of your building and how fast you want to change the air. Follow these five steps:

  1. Measure the buildingLength × width × height gives the volume in cubic metres.
  2. Choose the air changes per hour (ACH)Around 20–30 for garment floors and workshops; higher for dyeing and hot process areas.
  3. Calculate total airflowBuilding volume × ACH = airflow needed in m³/h.
  4. Pick the fan sizeChoose a model from the size table, usually a large 48″–54″ fan for big floors.
  5. Divide and placeTotal airflow ÷ one fan’s airflow = number of fans. Fit them on one wall with fresh-air inlets on the opposite wall.

Example: a 40 m × 20 m × 4 m garment floor = 3,200 m³. At 25 ACH you need 80,000 m³/h, which is about two 54″ fans (44,000 m³/h each).

Industrial exhaust fan sizes from 16 to 62 inch with airflow up to 55,000 m³/h

Exhaust Fan vs Axial Blower

Industrial exhaust fan Axial blower
Mounting Wall or window opening Inside a duct
Air volume Very high High
Pressure Low (no duct) Low to medium
Best for Whole-floor ventilation, cooling pad systems Ducted supply or exhaust, basements
Cost per m³/h Lowest Medium

Need air moved through ductwork instead? See our axial blower fan.

Installation and Maintenance Tips

  • Install the fans on the wall facing away from the wind, with fresh-air inlets on the opposite side.
  • Keep at least one fan diameter of clear space outside the fan.
  • Use a correctly rated starter and overload protection for 3-phase motors.
  • Clean the louvers and blades every month in dusty or lint-heavy areas.
  • Check belt tension, bearings and bolts every three months.

Why Buy Your Industrial Exhaust Fan from NextEdge BD?

  • Free sizingWe calculate how many fans you need for your floor.
  • Complete cooling systemExhaust fans, cooling pads, blowers and installation from one partner.
  • Delivery across BangladeshDhaka, Gazipur, Narayanganj, Chattogram and beyond.
  • After-sales supportService, motors and spare parts when you need them.

See our full range of industrial ventilation products.

Frequently Asked Questions

What is the industrial exhaust fan price in Bangladesh?

The price depends on the fan size, motor and quantity. Send us your floor size and we will quote the right model.

Which sizes are available?

Frame sizes from 16″ to 62″, with airflow from about 4,600 m³/h up to 55,000 m³/h.

Do the fans need 3-phase power?

The standard models run on 380 V, 3-phase, 50 Hz. Ask us if you need a single-phase option.

Can I use exhaust fans with cooling pads?

Yes. Exhaust fans on one wall and cooling pads on the opposite wall make an evaporative cooling system that can lower the indoor temperature by several degrees.

Do you provide installation?

Yes. NextEdge BD arranges site survey, installation and after-sales service across Bangladesh.

Need industrial exhaust fans for your factory? Send us your floor size – we will tell you how many fans you need, free of charge.

Get a free sizing quote

Request a quote

Send us the requirement. We will quote it.